List of accumulation tanks:
HSK ACCUMULATION TANKS with
a stainless-steel heat exchanger for DHW
Tanks for heating water accumulation with an
immersed stainless-steel heat exchanger for DHW, a thermally stratified tank for
the return line from the heating system, 2 steel heating coils (e.g. for
connecting solar collectors). An electric heating rod can be inserted and
further thermal loads connected.
- max. working pressure: 6 bar
- max. working pressure of the DHW heat exchanger: 6 bar
- max. working temperature: 95°C
|
The accumulation tank:
-
1 top nipple with G 1“ inner thread- for connecting an air vent valve
-
5 side nipples with G 6/4“ inner thread- for connection to the heating system
-
1 side nipple with G 6/4“ inner thread- to accommodate a heating rod
-
6 side nipples with G 1/2“ inner thread- to accommodate probes
-
4 side nipples with G 1“ inner thread- for connecting 2 heating coils
|
Immersed stainless-steel heat exchanger for DHW:
- 2 side nipples with G 5/4“ stainless-steel inner thread - inlet,outlet
|
TYPE
(liters) |
height
(mm) |
diameter
(mm) |
surface of the heating coil
(m2) |
Code |
| s1 |
s2 |
TUV |
| HSK 500 |
1720 |
650 |
- |
2,3 |
5,7 |
7662 |
| HSK 800 |
1930 |
790 |
2 |
3 |
7,2 |
7663 |
| HSK 1000 |
2110 |
790 |
3 |
3,5 |
7,2 |
7506 |
| HSK 1500 |
2240 |
1000 |
3,5 |
4,5 |
8,5 |
7686 |
| HSK 2000 |
2380 |
1100 |
4,1 |
5,5 |
11,5 |
7687 |
|
For HSK accumulation tanks we supply detachable 120mm thick soft polyurethane
insulation with a white leatherette surface.
Installation and User Guide Manual for HSK Accumulation Tank
DUO-E ACCUMULATION TANKS with an immersed DHW tank
Combination tanks for heating water accumulation,
with a sanitary water tank inserted, with a heating coil (e.g. to connect solar
collectors), with the possibility of inserting an electric heating rod and connecting further heat sources. The inner surface of the inside
tank is enameled according to DIN 4753. The inside tank is equipped with a
magnesium anode rod.
- max. working pressure 3 bar
- max. working pressure of the DHW tank 10 bar
- max. working temperature 95°C
|
The accumulation tank:
-
5+1 side nipples with G 1“ inner thread- for connecting to a heating system
-
2 side nipple with G 6/4“ inner thread- for placing an electric heating rod
-
4 side nipples with G 1/2“ inner thread- for placing probes
-
1 top nipple with G 1/2“ inner thread- for connecting a heating coil (G1-Only)
|
The immersed tank:
- 2 top apertures with G 1“ inner thread- inlet, outlet
- 1 top aperture for circulation
- 1 top aperture with G 1/2“ inner thread - for sanitary water probes
- 1 magnesium anode rod G 5/4“
|
TYPE
In total / DHW (liters) |
height
(mm) |
diameter
(mm) |
surface of the heating coil (m2) |
Code |
| DUO-E 600/150 |
1724 |
750 |
2,3 |
7322 |
| DUO-E 750/200 |
1979 |
750 |
2,5 |
7323 |
| DUO-E 1000/220 |
2089 |
800 |
2,8 |
7324 |
| DUO-E 1500/300 |
2254 |
1000 |
3,9 |
7325 |
|
DUO-E accumulation tanks are supplied with 100 mm thick
insulation of soft polyurethane with white leatherette surface.
Instalation and Operational Manual for Accumulation Tanks DUO-E
|
- max. working pressure 3 bar
- max. working pressure of the DHW tank 10 bar
- max. working temperature 95°C |
The accumulation tank:
-
5 side nipples with G 5/4“ inner thread - for connecting to a heating system
- 1 side nipple with G 1“ inner thread - for connecting to a heating system
- 1 side nipple with G 6/4“ inner thread - for placing an electric heating rod
-
4 nipples with G 1/2“ inner thread - for placing probes
- 2 top nipples with G1“ inner thread - for connecting a heating coil(G1 only)
|
|
The immersed tank:
- 3 top inlets with G 3/4“ inner thread - inlet, outlet, circulation
- 1 top aperture with G1/2“ inner thread - for DHW probe
- 1 magnesium anode G 5/4“
|
|
TYPE
Total/DHW
(liters)
|
height
(mm)
|
diameter
(mm)
|
surface of the heating coil
(m2)
|
Code |
| DUO-E 380/120 G0 |
1870 |
700 |
- |
9498 |
| DUO-E 380/120 G1 |
1870 |
700 |
2,1 |
9356 |
|
|
DUO-E G0 and G1 accumulation tanks are supplied with 75 mm thick insulation of hard polyurethane with white leatherette surface.The insulation is not detachable.
|
Accessories
A whole range of accessories is available for
accumulation tanks.
|