Elesta, a traditional Swiss manufacturer of regulation
equipment, offers a line of regulators for economic and
comfort control of a wide range of applications, from
simple applications to most complex systems involving
several heat sources and many heating circuits.
|
The regulator
keeps evaluating both the room temperature and
the outdoor temperature and calculates an
optimum heating mode and boiler operation. The
regulator uses continuous evaluation of both
inner and outer temperatures and heating water
temperature for determining the characteristic
of the building and for continuous modification
of the optimum heating mode. This ability of the
regulator to learn and subsequently optimize
further regulation calculations is decisive for
reaching both comfort and economy of operation.
The regulators
are manufactured in many executions for various
typical applications, each regulator has many
adjustable service parameters. Thanks to it, the
regulator can be configured ideally for a
specific heating system and wishes of the users.
Besides heating it can control warming sanitary
water, pool water, pumps and valves of mixing
circuits, switch or connect another heat source
or boiler cascade, protect your boiler against
low-temperature corrosion by controlling the
return water temperature. This all is reached
with simple handling and user comfort. |
 |
BASIC VERSIONS OF THE DIGITAL REGULATORS:
DOMOTESTA RDO 100
- Eeasy setting by means of potentiometers.
- Controls a boiler, mixing valve and warms up DHW
(type-dependent).
- Clock selection - analog daily, weekly, or
digital.
- Frost protection of the whole heating system.
- Room remote control can be used.
DOMOTESTA RDO 200
- Comfort control by means of a keyboard and
display.
- Control of boiler, mixing valve and DHW warming
with circulation according to time schedule.
- DHW protection against Legionella bacteria.
- Frost protection of the whole heating system.
- Room remote control can be used, "holiday mode“
offers an easy transition to setback mode for times
when you are e.g. on holidays.
DOMOTESTA RDO 300
- Can be connected into complex regulation systems
via bus interface.
- Programming may be done both digitally and from
a computer.
- Up to 4 heat sources and 7 mixing circuits can
be controlled.
- DHW warming in time mode.
- Each boiler in a cascade may have its separate
control of return water temperature.
Regulator overview

Application examples:
 |
The
regulator can control warming DHW through
solar collectors and in case of insufficient
temperature it starts a boiler to heat water
in the tank. The circulation pump is
switched on when the water in collectors
reaches higher temperature than in the tank,
and in case the collectors cool down, the
pump goes off. The function of tank cooling
can be used when critical values are
exceeded. |
 |
The
regulator controls mixed heating circuit. In
case when more mixed heating circuits shall
be controlled, the regulator enables
connecting a module for mixed heating
circuit. One regulator can serve max. 7
mixed heating circuits. Heating curves,
required temperatures and weekly time
schedules can be set differently for each
circuit. |
 |
The
regulator can control a heating system that
will use to maximum alternative energy
sources. When solar collectors, a heat pump
and a back-up electric boiler are installed,
the regulator will prefer using the solar
heat first for DHW and then for heating
(vice versa also possible). When solar
energy is insufficient, the heat pump is
switched on. Only for very low outside
temperatures, when even the heat pump is not
sufficient, the electric boiler is switched
on. The accumulation tank may be used also
for pool heating and the regulator will
ensure switching the appropriate source. |
 |
Boiler
cascade may be controlled by additional
boiler modules that communicate with the
regulator. For protection of boilers and
thermal dissipation decrease, the min.
temperature of return water can be
controlled either separately for each
boiler, or jointly for the whole cascade. In
case of 2-stage solutions, switching can be
set either to first stages first and then
the second stages, or full output of the
first boiler first and only then the next
boiler. |
Accessories
We supply a whole range of accessories for Elesta
regulators: remote controls, modules, sensors, base
plates etc.
|