Programmable
electronic room thermostats with a weekly program are intended for a comfort
room temperature control according to a preset time schedule. Energy is thus
saved and thermal comfort maintained. They can be used for both heating and
cooling. These thermostats are all equipped with an easy-to read LC display
showing room temperature, time and weekday, status of the output relay (boiler
ON/OFF) and the current mode (setback - comfort - antifrost). The mode can be
changed by simple pressing a key.
Thermostat TP01
This thermostat
enables programming 4 changes for workdays and Saturday with Sunday. 2
temperature levels can be set (setback and comfort) within a range of
5-35 °C. Besides that, antifrost mode can be activated..
|
Thermostat TP07
This thermostat
enables setting 4 different temperatures in 4 time sections for each
weekday, the temperature difference can be selected. Heat
anticipator can be switched on - heating is switched on in advance so
that the required temperature is reached at the preset time. Three modes
with a fixed temperature (holiday operation, antifrost mode, party
function).
|
Thermostat TP08
This room thermostat
offers a selection from eight preset programs incl. the antifrost one,
or creating further eight userdefined programs. 2 temperature levels
(set-back or comfort) can be set in the range from 5°C to 35°C. Time
program is shown on the display.
|
instalation manual TP01 |
instalation manual TP07 |
instalation manual TP08
|
| TECHNICAL DATA: |
TP 01 |
TP 07 |
TP 08 |
| Adjustable temperature range |
5 - 35°C in 0.5 steps |
7 - 35°C in 1.0 steps |
5 - 35°C in 0.5 steps |
| Adjustable temp. difference |
no |
yes 0,5 - 1,5°C |
no |
| Reading interval |
10 s |
10 s |
10 s |
| Antifrost temperature |
5°C |
5°C |
5°C |
| Number of weekly programs |
1+ antifrost |
1+ antifrost |
7+8+ antifrost |
| Programs for days |
Mo-Fr,Sa,Su |
Mo,Tu,We,Th,Fr,Sa,Su |
Mo,Tu,We,Th,Fr,Sa,Su |
Number of possible changes
per day |
4 in 10-min. steps |
4 in 15min. steps |
24 in 1-hour steps |
| Max. contact load |
24-230VAC; 8(2)A |
24 - 230VAC; 5(2)A |
24-230VAC; 8(2)A |
| Power supply |
2x battery AA 1.5V |
2x battery AA 1.5V |
2x battery AA 1.5V |
| IP protection |
IP 30 |
IP30 |
IP 30 |
| Code |
6297 |
8180 |
6298 |
Max. current is given for resistance load, the number in brackets is
valid for induction load.
|