Regulus CS Pump Groups make a boiler
installation easier because they contain all the important
components necessary for boiler protection and proper operation of
space heating and DHW heating. They are designed to be mounted
directly on the boiler outlet pipe or on a wall.
List of pump groups:
CS TSV VDM Group
| CS TSV VDM Group is intended
for solid-fuel boilers with an accumulation tank, DHW
heating enabled
CS TSV VDM contains:
- circulation pump
- boiler pump
- TSV2 thermostatic mixing valve
- 2 ball valves for connection to a heating system
- 3-way mixing valve for a heating system
- mixing valve actuator (the version with an actuator only,
code 8118)
CS TSV maintains the return
temperature at 65°C, preventing condensation and clogging the boiler
by tar. Water for a heating system (i.e. its heating output) is
mixed by a 3-way mixing valve, controlled either manually or by an
electronic controller. The heat surplus is stored in an accumulation
tank and then supplied automatically when the boiler goes off.
| Type |
Code |
| CS TSV VDM Group, no el. actuator for a mixing
valve |
7700 |
| CS TSV VDM Group, with a 3-way valve electric
actuator |
8118 |
|
 |
CS VMX Group
| CS VMX Group is intended for all kinds of
boilers. Both heating water and boiler water get mixed
without throttling
CS VMX contains:
- circulation pump
- 2 ball valves with thermometers for connection to a heating
system
- 4-way mixing valve for both a heating system and a boiler
- mixing valve actuator (the version with an actuator only,
code 8118)
- automatic heating system bypass
CS VMX makes it possible to control both the return
temperature of a solid-fuel boiler and the output of a
heating system using one 4-way valve. Thanks to
throttle-free regulation it can be used also for boilers
with an integrated pump (usually gas-fired ones). Noise of
closing thermostatic valves can be also eliminated using a
bypass with an adjustable pressure difference.
| Type |
Code |
| CS VMX Group, no el. actuator for a mixing valve |
8117 |
| CS VMX Group, with a 3-way valve electric
actuator |
7849 |
|
 |
CS TSV Group
| CS TSV Group is intended for
solid-fuel boilers, no accumulation tank, DHW heating
enabled
CS TSV contains:
- circulation pump
- boiler pump
- TSV2 thermostatic mixing valve
- 2 ball valves for connection
CS TSV maintains the return temperature at 65°C, preventing
condensation and clogging the boiler by tar. Heating water
is mixed automatically to a temperature corresponding to the
boiler output. It can work at a low boiler output e.g. with
a boiler temperature of 75/65°C and a heating system
temperature of 50/40°C. The heating output is controlled
directly on the boiler - e.g. by an RT2 thermostatic
regulator or by a room controller.
| Type |
Code |
| CS TSV Group, automatic mixing |
7699 |
|
 |
|