RegulusRGMAT Load Units have the same boiler protection function as TSV valves and, moreover, they make installation easier because they are also equipped with boiler circulation pumps and other elements. RegulusTOP Load Units with a load valve and actuator for mixing to a constant temperature are of similar type.
RegulusBIO Load Units – for boiler return line or heating system – involve also components necessary for proper operation of both space and DHW heating. They help reduce the assembly time and costs.
They mix return water from a heating system (or thermal store) with boiler flow water, keeping the return water temperature to boiler at the preset min. value.
We offer several models of load units that differ in their components:
RegulusRGMAT (formerly called REGOMAT)
RegulusTOP (formerly called REGOMIX)
ThermoMat 2.0
A float type non-return valve in ThermoMat load units permits boiler cooling by gravity circulation during power failure, at the same time preventing thermal store from being cooled down via an extinguished boiler.
Load units are available in versions with min. output temperatures between 45 and 72°C.
RegulusBIO
These load units make boiler installation easier. They contain all the important components necessary for boiler protection and proper operation in both space- and water heating modes. They are designed to be mounted directly on a boiler flow piping or on a wall.
RegulusBIO Load Unit is designed for heating systems with a fireplace or solid fuel boiler, or possibly also with another switched heat source, a thermal store with DHW heating. The Unit is internally wired and hydraulically connected, including a power cord and 4 temperature sensors.